Catching Ledinegg Starvation in LOHC Microchannel Dehydrogenators Before It Reaches the Field
A parallel microchannel dehydrogenator can pass every steady-state acceptance run and still starve one of its channels in the first month of service, because the instability that does it only exists once hydrogen release is vigorous enough to turn each channel into a two-phase flow path. At part load the liquid carrier dominates the pressure drop and the channels share flow politely. At rated heat flux the gas fraction rises, the channel pressure drop curve folds over, and a single partially fouled channel can lose its liquid supply, overheat, and begin cracking the carrier. The qualification plan has to create that condition on purpose and then watch whether the rest of the module holds.
Why the failure hides at part load
Dehydrogenation of a carrier such as perhydro-dibenzyltoluene is strongly endothermic, so every channel's conversion is set by how much heat it receives relative to how much liquid passes through it. A channel that receives slightly less liquid converts a larger fraction, generates proportionally more gas, and in the region where the two-phase pressure drop increases as liquid flow falls, it sheds even more liquid to its neighbours. That is the Ledinegg mechanism borrowed from boiling channels, and it is self-reinforcing: the starved channel runs hotter, cokes faster, and the coke raises its resistance further. Below roughly half of rated throughput (an estimate that depends on channel geometry and the carrier), the liquid term usually dominates and the slope never turns negative, which is why bench tests and commissioning runs at reduced duty tend to look clean. The behaviour is a property of the full load operating point, not of the hardware alone.
The test that maps the fold
Hold the heater zones at the rated heat flux and sweep the total liquid feed downward in small steps from above design flow, recording module pressure drop and every channel's outlet temperature at each plateau after it has settled thermally. Plotting pressure drop against flow gives the demand curve, and the test is looking for the point where its slope goes to zero and then negative; if that point sits inside the operating envelope, the distributor is not doing its job. The inlet restriction, whether orifices, a manifold plate or a porous distributor, is what keeps the system stable, because a stiff, single-phase pressure drop upstream of each channel turns the combined curve positive again. A practical decision rule: the restrictor's single-phase pressure drop at design flow must exceed the largest negative excursion of the channel demand curve across the whole envelope, and if the sweep shows the combined curve flattening anywhere, you add restriction before you add anything else. Do the sweep with fresh carrier and again with carrier that has been through several hydrogenation cycles, because degraded carrier shifts viscosity and the gas release onset.
Injecting the single fault
With the demand curve shown to be positive, put a calibrated partial blockage into one channel, an insert that removes a known fraction of its flow area, run the module at full rated duty, and require that the blocked channel's outlet temperature stays within a set band of the module mean, 8 K in a typical specification, while its neighbours absorb the redistributed flow without leaving that band themselves. Repeat with one heater zone switched off instead of a blockage, since a cold zone produces the opposite imbalance and tests whether the control loop overcorrects the remaining zones. Sample the hydrogen product downstream of the purification stage against the hydrogen fuel quality standards for fuel cell use, because carrier cracking in a hot channel shows up first as light hydrocarbons and methylfluorene type byproducts, well before any thermocouple alarm. The pass criterion is a stable new equilibrium, not survival: the outlet temperature spread and the product impurity level must both stop moving.
Run the fault case long enough to read the slope of the blocked channel's pressure drop over time rather than its endpoint, because coking rate is the real signal and a few hours at full duty (an estimate; the time constant scales with temperature margin) separates a channel that has settled from one that is still sliding toward starvation, which leaves the open decision of whether you buy that run time on the test stand or accept it as a monitored risk during the first field campaign.
Technical FAQ: Can the per-channel temperature measurement be replaced by module-level pressure drop alone?
Not for qualification. A single starving channel among dozens barely moves the total pressure drop, because its neighbours absorb the flow and the manifold sees almost the same resistance. Outlet temperature per channel, or at least per channel group small enough that one bad channel moves the group mean beyond the band, is what makes the fault visible. Module pressure drop is still useful in service as a slow trend once qualification has shown which drift rates are benign.